Medical Banner

자산 발행인

의학적 이미징

고속 초저소음 감지기 솔루션은 컴퓨터 단층 촬영 (CT) 스캐닝 장비 제조업체들로 하여금 환자를 방사선에 적게 노출시키면서 CT 정지 영상을 생성할 수 있게 해줍니다. ams의 혁신적인 감지기 기술 개발은 의료 전문가들이 더 분명한 사진을 통해 더 나은 진료/치료 서비스를 제공할 수 있음을 뜻합니다.

Featured products

제품 데이터시트 데모보드
AS5900

The AS5900 device is a low noise, 128-channel current-to-digital converter that enables the readout of the photodiodes with highest sensitivity. High-resolution CT imaging can be achieved up to 26-bits resolution. Its 128-low-noise and high linear converter channels provide an increased gray scale, improved contrast and reduce artifacts of 3D CT images. The low power consumption of 1mW per channel reduces self-heating effects and the overall power consumption of the system. An integrated temperature sensor allows the calibration of temperature drifts of the X-ray detector modules.

자산 발행인

바이탈 사인 센싱

생체센서 제품군에는 심박수 측정, 광용적맥파 (PPG), 심전도 (ECG)를 위한 알고리즘이 포함된 최초의 광센서 모듈이 내장되어 있습니다. 이 모듈은 웨어러블 기기, 의료용 모니터, 산업 장비 및 휴대기기 등 다양한 최종 제품에 이상적입니다. ams의 생체센서는 저소음 아날로그 및 광학 프런트 엔드 및 맞춤형 ams 소프트웨어와 알고리즘들이 조합되어 있으므로 업계에서 가장 우수한 정확도 등급을 달성할 수 있습니다. 휴대기기 감광 분야에 전문성을 보유하고 있는 ams는 설계자들이 성공적인 구현을 빠르게 실현할 수 있도록 OEM 업체들에 전기, 기계 및 광학 설계 지침을 제공합니다.

Featured products

제품 데이터시트 데모보드
AS7000

The AS7000 solution contains the AS7000 module including the LEDs, photo-sensor, analog front-end (AFE) and controller as well as application software required to implement an accurate optical HRM/HRV fitness band product.

The module also enables skin temperature and skin resistivity measurements by providing interfaces to external sensors.

The AS7000’s low power design is particularly well suited to application in fitness bands, smart watches and sports watches, in which board space is limited and in which users look for extended, multi-day intervals between battery recharges.

AS7024

The operation of the AS7024 is based on photoplethysmography (PPG) and electrocardiogram (ECG). PPG is the most used HRM method which measures the pulse rate by sampling light modulated by the blood vessels, which expand and contract as blood pulses through them. ECG is the reference for any measurement of the bio potential generated by the heart.
The AS7024 is supported by algorithms converting the PPG and ECG readings into digital HRM, HRV and Blood Pressure values. The module includes the LEDs, photo-sensor, analog front-end (AFE) and sequencer as well as application software. In addition to HRM/HRV and Blood Pressure, the module also enables skin temperature and skin resistivity measurements by providing interfaces to external sensors.
The AS7024’s low-power design and small from factor is particularly well suited to application in fitness bands, smart watches, sports watches and smart patches, in which board space is limited and in which users look for extended, multi-day intervals between battery recharges.

Not Recommended for New Designs

ams AG does not recommend using AS7024 for new designs. Please see AS7026GG for possible replacement or contact your local sales representative for further information.

AS7026GG

The operation of the AS7026 is based on photoplethysmography (PPG) and electrocardiogram (ECG).
PPG is the most used HRM method which measures the pulse rate by sampling light modulated by the blood vessels, which expand and contract as blood pulses through them. ECG is the reference for any measurement of the bio potential generated by the heart. The AS7026 is supported by algorithms converting the PPG and ECG readings into digital HRM, HRV and Continuous Blood Pressure values. The cuff-less Blood Pressure Measurement has been optimized to fulfill the IEEE Std 1708-2014.
The module includes the LEDs, photo-sensor, analog front-end (AFE) and sequencer as well as application software. In addition to HRM/HRV and Blood Pressure, the module also enables skin temperature and skin resistivity measurements by providing interfaces to external sensors.
The AS7026’s low-power design and small from factor is particularly well suited to application in fitness bands, smart watches, sports watches and smart patches, in which board space is limited and in which users look for extended, multi-day intervals between battery recharges.